T90
ProducingPV array · LONGi Hi-MO 6 bifacial · Totalp test site
Tilt / azimuth
90° / 184°
Front irradiance
541 W/m²
Rear irradiance
96 W/m²
Bifacial gain
+13.4 %
Snow on modules
3 %
Lost to snow
3 kWh
Last slide-off
08:16
Rated power
24 kWp
Output now
13.5 kW
Energy today
113 kWh
Lifetime
205 MWh
Availability
98.43 %
Runtime
5,690 h
Next service
in 2,198 h
Last seen
13:59:48
Total
176
Normal
169
Underperforming
5
Fault
2
Snow covered
0
Needing attention
T01-B1-3
Hot spot on the front glass
Tree 1 · wall B · wing 1 · row 3
85 % of expected
UnderperformingT02-B2-4
Soiling from rockfall dust
Tree 2 · wall B · wing 2 · row 4
82 % of expected
UnderperformingT03-A1-4
Bypass diode shorted
Tree 3 · wall A · wing 1 · row 4
67 % of expected
UnderperformingT04-B2-1
Hot spot on the front glass
Tree 4 · wall B · wing 2 · row 1
79 % of expected
UnderperformingT05-A2-1
Hot spot on the front glass
Tree 5 · wall A · wing 2 · row 1
78 % of expected
UnderperformingT10-B1-3
String fuse blown
Tree 10 · wall B · wing 1 · row 3
T11-B2-3
Junction box failure
Tree 11 · wall B · wing 2 · row 3
Telemetry
Front irradiance
541.00 W/m²
Rear irradiance
96.00 W/m²
Module temperature
10.50 °C
Snow on modules
3.00 %
Wind gust
11.40 m/s
Snow load
2.53 kN/m²
String voltage
1,211.00 V
String current
7.61 A
Ambient
-3.10 °C
No alarms on this asset.