PV-06

Producing

PV array · LONGi Hi-MO 6 bifacial · Saflisch

ModulesFault1Underperforming1
Effective irradiance, W/m²0425850
Producing
Live
Now
Polled every 5 seconds; the 3D model follows these values.
63% of rated

Tilt / azimuth

65° / 177°

Front irradiance

639 W/m²

Rear irradiance

127 W/m²

Bifacial gain

+14.9 %

Snow on modules

3 %

Lost to snow

599 kWh

Last slide-off

09:50

Rated power

1,100 kWp

Output now

692.3 kW

Energy today

4,839 kWh

Lifetime

1,436 MWh

Availability

95.52 %

Runtime

1,299 h

Next service

in 1,332 h

Last seen

13:59:49

Modules
Module health
Every module reports on its own. Hover one in the 3D view for its reading; faults blink red, underperforming modules blink amber.

Total

60

Normal

58

Underperforming

1

Fault

1

Snow covered

0

Needing attention

R1-03B

Bypass diode shorted

Table 1 · column 3 · upper row

63 % of expected

Underperforming

R3-10B

Open DC connector

Table 3 · column 10 · upper row

Fault

Telemetry

Front irradiance

639.00 W/m²

Rear irradiance

127.00 W/m²

Module temperature

15.40 °C

Snow on modules

3.00 %

Wind gust

8.50 m/s

Snow load

2.18 kN/m²

String voltage

1,207.00 V

String current

8.32 A

Ambient

-0.60 °C

History
Power and snow-free potential
Active power against what the asset would make with clean modules. The gap is the snow loss.
Today
Hourly energy
MWh delivered and lost to snow, hour by hour since midnight.
Alarms
Asset alarms
Open and recent events for this asset.

No alarms on this asset.