PV-09

Producing

PV array · LONGi Hi-MO 6 bifacial · Gondo

ModulesFault3Underperforming10
Effective irradiance, W/m²0425850
Producing
Live
Now
Polled every 5 seconds; the 3D model follows these values.
64% of rated

Tilt / azimuth

90° / 176°

Front irradiance

651 W/m²

Rear irradiance

105 W/m²

Bifacial gain

+12.1 %

Snow on modules

3 %

Lost to snow

160 kWh

Last slide-off

07:54

Rated power

1,250 kWp

Output now

798.3 kW

Energy today

5,785 kWh

Lifetime

3,444 MWh

Availability

95.23 %

Runtime

1,113 h

Next service

in 150 h

Last seen

13:59:52

Modules
Module health
Every module reports on its own. Hover one in the 3D view for its reading; faults blink red, underperforming modules blink amber.

Total

176

Normal

163

Underperforming

10

Fault

3

Snow covered

0

Needing attention

T01-A1-4

Cracked cells

Tree 1 · wall A · wing 1 · row 4

65 % of expected

Underperforming

T01-B2-3

Cracked cells

Tree 1 · wall B · wing 2 · row 3

75 % of expected

Underperforming

T02-A2-4

Shaded by a snow cornice

Tree 2 · wall A · wing 2 · row 4

45 % of expected

Underperforming

T03-A2-1

Potential-induced degradation

Tree 3 · wall A · wing 2 · row 1

78 % of expected

Underperforming

T04-A1-3

String fuse blown

Tree 4 · wall A · wing 1 · row 3

Fault

T04-B2-3

Shaded by a snow cornice

Tree 4 · wall B · wing 2 · row 3

51 % of expected

Underperforming

T08-B1-2

Broken glass after hail

Tree 8 · wall B · wing 1 · row 2

Fault

T09-B1-3

Soiling from rockfall dust

Tree 9 · wall B · wing 1 · row 3

84 % of expected

Underperforming

T09-B2-4

Open DC connector

Tree 9 · wall B · wing 2 · row 4

Fault

T10-A1-2

Shaded by a snow cornice

Tree 10 · wall A · wing 1 · row 2

50 % of expected

Underperforming

T10-A1-3

Bypass diode shorted

Tree 10 · wall A · wing 1 · row 3

66 % of expected

Underperforming

T10-A2-4

Hot spot on the front glass

Tree 10 · wall A · wing 2 · row 4

79 % of expected

Underperforming

T11-B1-2

Hot spot on the front glass

Tree 11 · wall B · wing 1 · row 2

70 % of expected

Underperforming

Telemetry

Front irradiance

651.00 W/m²

Rear irradiance

105.00 W/m²

Module temperature

18.50 °C

Snow on modules

3.00 %

Wind gust

6.40 m/s

Snow load

1.24 kN/m²

String voltage

1,202.00 V

String current

8.57 A

Ambient

2.30 °C

History
Power and snow-free potential
Active power against what the asset would make with clean modules. The gap is the snow loss.
Today
Hourly energy
MWh delivered and lost to snow, hour by hour since midnight.
Alarms
Asset alarms
Open and recent events for this asset.

No alarms on this asset.