PV-10

Producing

PV array · LONGi Hi-MO 6 bifacial · Gondo

ModulesUnderperforming6
Effective irradiance, W/m²0425850
Producing
Live
Now
Polled every 5 seconds; the 3D model follows these values.
62% of rated

Tilt / azimuth

90° / 176°

Front irradiance

651 W/m²

Rear irradiance

105 W/m²

Bifacial gain

+12.1 %

Snow on modules

3 %

Lost to snow

154 kWh

Last slide-off

07:27

Rated power

1,250 kWp

Output now

774.3 kW

Energy today

5,612 kWh

Lifetime

3,444 MWh

Availability

95.53 %

Runtime

993 h

Next service

in 846 h

Last seen

13:59:50

Modules
Module health
Every module reports on its own. Hover one in the 3D view for its reading; faults blink red, underperforming modules blink amber.

Total

176

Normal

170

Underperforming

6

Fault

0

Snow covered

0

Needing attention

T01-A2-1

Potential-induced degradation

Tree 1 · wall A · wing 2 · row 1

80 % of expected

Underperforming

T01-B2-3

Cracked cells

Tree 1 · wall B · wing 2 · row 3

81 % of expected

Underperforming

T03-A1-3

Cracked cells

Tree 3 · wall A · wing 1 · row 3

71 % of expected

Underperforming

T04-A2-3

Cracked cells

Tree 4 · wall A · wing 2 · row 3

67 % of expected

Underperforming

T05-A2-4

Bypass diode shorted

Tree 5 · wall A · wing 2 · row 4

61 % of expected

Underperforming

T07-B2-2

Soiling from rockfall dust

Tree 7 · wall B · wing 2 · row 2

84 % of expected

Underperforming

Telemetry

Front irradiance

651.00 W/m²

Rear irradiance

105.00 W/m²

Module temperature

18.50 °C

Snow on modules

3.00 %

Wind gust

6.40 m/s

Snow load

1.24 kN/m²

String voltage

1,201.00 V

String current

8.21 A

Ambient

2.30 °C

History
Power and snow-free potential
Active power against what the asset would make with clean modules. The gap is the snow loss.
Today
Hourly energy
MWh delivered and lost to snow, hour by hour since midnight.
Alarms
Asset alarms
Open and recent events for this asset.

No alarms on this asset.